CALIBRIERSTANDARDS

KS.jpg
We offer a range of high quality Transfer- and Calibrationtandards to calibrate spectrometers and radiometers, for spectrale irradiance ([W/m²/nm]) in the UV/VIS/NIR range and photometric units ([lm], [cd]). They are traceble to PTB or NPL.
Our Quartz-Halogen- and Deuterium standards are produced as single lamps and complete systems including lamp holders and very stable, temperature compensated, constant current powersupply.

Wavelength range: 200 - 2500 nm.

 
 
 
 
 
 
ks-j1011_105.jpg

Transfer Standard QTH: Labor/Transportable

Portable spectral irradiance transfere standard (Halogen Lamp, 200 W), based on the developement of the PTB (Physikalisch Technische Bundesanstalt, Braunschweig). Technical improvements allowe a simple and quick change of the lamp by up keeping of the original lamp certificate.

Wavelength range: 250 - 2500 nm.
 
 
 
 
 
 
dls-j1016.jpg

Transfer Standard D2:

This calibration standard for spectral irradiance (Deuterium Lamp, 30W) is based on the developement of the PTB (Physikalisch Technische Bundesanstalt, Braunschweig).

Wavelength range: 250 - 350 nm.
 
 
 
 
 
 
led-j1019.jpg

LED-J1019: LED Transfer Standard

LED Transfer Standard for photometric and colorimetric units, based on the developement of the PTB (Physikalisch Technische Bundesanstalt, Braunschweig).

Units: luminous flux [lm], luminous intensity [cd], dominant wavelength
 
 
 
 
 
 
KL_105.jpg

Calibration Standards

The accuracy of any spectroradiometric measurement system can only be as good as that of the standard source used for calibration. We manufacture a range of sources calibrated in our laboratory using NPL calibrated versions of the same product.

The following table is a representative but not complete list of devices available:
Product Standard of... Wavelength-range Units parameter
SRS8 Spectral Radiance 380-800nm mW/(sr.m².nm) Luminance (cd/m2)
SRS8-Q Spectral Radiance 300-1400nm mW/(sr.m².nm) Luminance (cd/m2)
SRS8/RI Spectral Radiant Intensity 380-2500nm mW/(sr.nm) Luminous intensity
CL2 Spectral Irradiance 250-3000nm mW/(m2.nm) Illuminance
CL3 Spectral Irradiance 200-400nm mW/(m2.nm) n/a
CL6 Spectral Irradiance 200-3000nm mW/(m2.nm) Illuminance
CL7 Spectral Irradiance 200-400nm mW/(m²nm) n/a
CL-Hg Wavelength, spectral lines 250-600nm nm n/a
TSRF Total Spectral Radiant Flux 300-800nm mW/nm Total luminous flux
Si-CAL Detector Responsivity 200-1100nm A/W n/a
Ge-CAL Detector Responsivity 900-1800nm A/W n/a
Please contact us for further information.
 
 
 
 
 